A Weak Password Requirements issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers…
icscert·CWE-521·Published 2017-06-30
A Weak Password Requirements issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected products use a numeric password with a small maximum character size for the password.
A Weak Password Requirements issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected products use a numeric password with a small maximum character size for the password.
Se detectó un problema de Requisitos de Contraseña Débiles en los controladores lógicos programables MicroLogix 1100 1763-L16AWA, Series A y B, versión 16.00 y anteriores; 1763-L16BBB, Serie A y B, versión 16.00 y anteriores; 1763-L16BWA, Serie A y B, versión 16.00 y anteriores; y 1763-L16DWD, Series A y B, versión 16.00 y anteriores de Allen-Bradley en Rockwell Automation y controladores lógicos programables MicroLogix 1400 1766-L32AWA, Series A y B, versión 16.00 y anteriores; 1766-L32BWA, Serie A y B, versión 16.00 y anteriores; 1766-L32BWAA, Serie A y B, versión 16.00 y anteriores; 1766-L32BXB, Serie A y B, versión 16.00 y anteriores; 1766-L32BXBA, Serie A y B, versión 16.00 y anteriores; y 1766-L32AWAA, Series A y B, versión 16.00 y anteriores de Allen-Bradley en Rockwell Automation. Los productos afectados usan una contraseña numérica con un pequeño tamaño máximo de caracteres para la contraseña.
| Version | Type | Source | Base | Exp | Impact | Vector |
|---|---|---|---|---|---|---|
| 2.0 | Primary | NVD | 5.0 | 10.0 | 2.9 | AV:N/AC:L/Au:N/C:P/I:N/A:N |
| 3.0 | Primary | NVD | 9.8 | 3.9 | 5.9 | CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
| 3.1 | Primary | cve.org | 9.8 | — | — | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
| 3.1 | Primary | cve.org | 9.8 | — | — | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
| 3.1 | Secondary | NVD | 9.8 | 3.9 | 5.9 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |