Sensitive Information Uncleared Before Debug/Power State Transition

BaseStableSimple2 CVEs
The product performs a power or debug state transition, but it does not clear sensitive information that should no longer be accessible due to changes to information access restrictions.

Extended description

A device or system frequently employs many power and sleep states during its normal operation (e.g., normal power, additional power, low power, hibernate, deep sleep, etc.). A device also may be operating within a debug condition. State transitions can happen from one power or debug state to another. If there is information available in the previous state which should not be available in the next state and is not properly removed before the transition into the next state, sensitive information may leak from the system.

Common consequences1

  • ConfidentialityIntegrityAvailabilityAccess ControlAccountabilityAuthenticationAuthorizationNon-RepudiationRead MemoryRead Application Data

    Sensitive information may be used to unlock additional capabilities of the device and take advantage of hidden functionalities which could be used to compromise device security.

Potential mitigations1

  1. Architecture and DesignImplementation

    During state transitions, information not needed in the next state should be removed before the transition to the next state.

Relationships2

CVEs referencing this CWE2

CVEDescriptionSeverityEPSSFlagsModified
CVE-2020-22656

In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300) before 3.6.2.0.795, Virtual SmartZone (vSZ) before 3.6.2.0.795, ZoneDirector 1100 9.10.2.0.130, ZoneDirector 1200 10.2.1.0.218, ZoneDirector 3000 10.2.1.0.218, ZoneDirector 5000 10.0.1.0.151, a vulnerability allows attackers to make the Secure Boot in failed attempts state (rfwd).

HIGH7.5
0.49%p38
2025-04-03
CVE-2023-41967

Sensitive information uncleared after debug/power state transition in the Controller 6000 could be abused by an attacker with knowledge of the Controller's default diagnostic password and physical access to the Controller to view its configuration through the diagnostic web pages. This issue affects: Gallagher Controller 6000 8.70 prior to vCR8.70.231204a (distributed in 8.70.2375 (MR5)), v8.60 or earlier.

MEDIUM4.6
0.31%p23
2024-11-21