A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1…
siemens·CWE-755·Published 2021-05-12
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition.
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition.
Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (Todas las versiones anteriores a V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (Todas las versiones anteriores a V16 Update 4). El cliente SmartVNC presenta un fallo al manejar una excepción apropiadamente si el proceso de ejecución del programa es modificado después de enviar un paquete desde el servidor, lo que podría resultar en una condición de Denegación de Servicio
| Version | Type | Source | Base | Exp | Impact | Vector |
|---|---|---|---|---|---|---|
| 2.0 | Primary | NVD | 5.0 | 10.0 | 2.9 | AV:N/AC:L/Au:N/C:N/I:N/A:P |
| 3.1 | Primary | cve.org | 7.5 | — | — | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H |
| 3.1 | Primary | NVD | 7.5 | 3.9 | 3.6 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H |
| 3.1 | Primary | cve.org | 7.5 | — | — | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H |
| 3.1 | Secondary | NVD | 7.5 | 3.9 | 3.6 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H |